Book a demo

Carestream 8100 3D

Fast scanning times and accessibility for all patient sizes and mobility

 

Image

Bundle your purchase with our clear aligner system!

4th case free when you buy a new intaoral or CBCT unit.  Find out more.
Offer valid until 31 December 2024. T&Cs apply

 

A proven and simple CBCT unit

The affordable and easy-to-use Carestream 8100 3D imaging system makes digital dentistry technology simple and easy to use for everyone in your practice. It is also capable of taking both 2D and 3D images, so that you can get the digital imaging most suitable for your case, combining convenience and efficiency.

 

The CS 8100 has won over 15 international prizes, including the RedDot Design Award 2013

 

Convenient for allDentist and patient using the CS 8100

Whether you are the user or the patient, the CS 8100 3D makes image acquisition quick and simple.

  • Intuitive interface and letter landmarks on the bite block simplify the examination process
  • Open, face-to-face design puts patients at ease and promotes comfort
  • Fast scanning times (7 seconds minimum) minimise the risk of movement and reduce retakes
  • Accessible to patients of all sizes and individuals who use wheelchairs, due to the ultra-compact unit, easily fitting in tight spaces

 

Multi-functional System

From traditional panoramic exams to endodontics, implant planning and oral surgery applications, the CS 8100 3D is capable of far more thanCS 8100 Scan the average 3D unit.

  • Optional cephalometric configuration available
  • Award-winning technology delivers superb panoramic images in seconds
  • Accurate 3D representations ensure optimal diagnostic results
  • CADCAM abilities empower you to perform more procedures in your practice

 

Precision from All Angles

The CS 8100 3D is designed for accuracy, with a high-frequency X-ray generator, 4T CMOS (Complementary Metal-Oxide-Semiconductor)  sensor and vibration-free motion system working together to ensure smooth image capture.

  • Resolution up to 75 µm is ideal for endodontic indications
  • 3D images offer more accurate views of dental anatomies
  • View areas of interest from every angle with one-to-one accuracy
 
 

Safer Examinations

Combining CBCT technology with a selectable field of view and low dose imaging, the CS 8100 3D is designed to limit radiation dose and ensure safer exams.

  • Low-dose mode delivers high-quality 3D images at the same or lower dose as a standard panoramic exam
  • Flexible fields of view confine radiation to the area of interest
  • Control settings such as size, resolution and dose for each exam

 

Switch to BioHorizons
 
 
 
Advance

What is Henry Schein Advance?

If you're about to invest in dental equipment, you could be able to combine your costs and benefit from Advance!

Eligible customers will receive a rebate based on their merchandise* and clear aligner spend, which can be offset against your monthly equipment repayment cost.

 

*Merchandise rebate is calculated based on an increase in spend.

CS 8100 3D: The Wait is Over

Detailed below are a list of error messages which may appear on your unit’s screen. Click on a message to see the possible cause of the error or warning and what action should be taken.

Occasionally, malfunctions can occur during use in the event of an incorrect action. An error message is displayed on the popup on the Acquisition interface System Status Screen.

 

If you do not find the problem below or the action you take does not solve the problem, please contact our support team on 08700 10 20 46. In order to help you, have the model serial number of your unit and details of the error code message.

Err_S_8100_CJ848_GENERATOR_36865

Possible Cause

Handswitch was released before the end of exposure.

The user has released the exposure button prematurely.

  Action

Relaunch the acquisition and hold the exposure button until the end of the acquisition cycle.

X-ray tube cooling

Possible Cause

Cooling in progress.

  Action

Wait until the Generator Cooling Indicator on the Acquisition interface reaches zero.

Thermal security

Possible Cause

Cooling in progress.

  Action

Wait until the Generator Cooling Indicator on the Acquisition interface reaches zero.

Release handswitch

Possible Cause

The acquisition has ended.

  Action

Release the exposure button of the x-ray remote control.

Start the acquisition

Possible Cause

The acquisition has been launched.

  Action

Keep pressing and holding the exposure button.

Upgrade of the firmware

Possible Cause

The system is being upgraded.

  Action

Wait for completion of the upgrade.

Monthly

Wipe the outer covers of the unit with a soft and dry cloth.


Annually

We recommend a general inspection of the unit carried out by an authorised service technician.


Controlling the Image Quality

To maintain optimum image quality, the image quality must be controlled once a month. To control the image quality, follow these steps:

  • On your desktop, double-click  Image. The CS 8100 3D Technician Tools window is displayed.

Image

  • In the left pane, double-click Image Quality Tool. The Image Quality Control window is displayed.

Image

  • Select the desired test and follow the on-screen instructions.

Future-proof your equipment today with our service contracts

We know an unexpected breakdown in your practice can be a headache for you and your patients - which is why we have put together a choice of 3 different service contracts to suit all budgets.

Annual service

To get optimum performance from your equipment and to conform to manufacturer’s recommendations, an annual service could be just what you’re looking for. These are carried out by our accredited team, who are all trained in-person by the manufacturer before they are sent to your practice.

Emergency breakdown service

We are never far away in an emergency. Unplanned breakdowns are a headache for any surgery. We are more than happy to help.

Find out more about our equipment servicing

Henry Schein Financial Service

Henry Schein Financial Services have access to a vast range of financial products and services that are offered by companies UK wide. If you seek financial support from a tied agent or company representative, they may only be able to advise and offer products from the company they represent but this is where we differ. Talk to us today about our range of equipment finance options or building works loans.

Find out more

Enquire
Enquire Now

Our equipment team will use the information you provide to respond to your query as promptly as possible.

You could ask about a FREE one-to-one consultation with one of our specialist team, quotation, demonstration of the latest equipment, or any other question you may have in helping you make an informed decision.

Contact Permission (not required)

We’d love to send you exclusive offers and latest news stories from Henry Schein Dental by e-mail. We’ll always treat your personal details with care and will never sell them to other companies for marketing purposes.

Ask a Question
Ask a question

Got a question you can't find an answer for? Pop it in the box below and we'll get back to you as soon as possible.

Contact Permission (not required)

We’d love to send you exclusive offers and latest news stories from Henry Schein Dental by e-mail. We’ll always treat your personal details with care and will never sell them to other companies for marketing purposes.

Henry Schein UK Holdings Limited t/a Henry Schein Dental is a limited company registered in England and Wales under registration number 11584480 and VAT registration number 573778979.
Its registered office is Medcare House, Centurion Close, Gillingham Business Park, Gillingham, Kent, ME8 0SB.


Henry Schein UK Holdings Limited is authorised and regulated by the Financial Conduct Authority and is entered on the Financial Services Register under firm reference number 708571.
Henry Schein UK Holdings Limited is a credit broker and not a lender.